Skip to main content Skip to search Skip to main navigation

PROFINET/CAN-Gateway, Layer 2

The PN/CAN gateway Layer 2 allows the connection of CAN devices with proprietary CAN protocols.

On the PROFINET network, the PN/CAN gateway is a PROFINET I/O device and supports transmission rates of up to 100 Mbit full duplex; on the CAN bus, up to 1 Mbit/s is supported.

The I/O data of the CAN nodes are mapped transparently and freely configurable into the PROFINET network and can thus be processed directly in the PLC. The PN/CAN gateway is integrated into the hardware configurator with a GSDML file and can be fully configured there. Further software tools for parameterization, or handling blocks for programming, are not necessary, which makes the use of the gateway uncomplicated.

The features MRP (media redundancy) as well as extensive diagnostic functions and an interface for online diagnosis complete the performance characteristics of the PN/CAN gateway.

  • Automatic and controlled receive and transmit objects for CAN frames with configurable identifier
  • Transmission objects can also be transmitted cyclically
  • Receive channel FIFO for receiving CAN frames with flexible identifier
  • Transmission channel FIFO for transmitting any CAN frames with flexible identifier
  • Up to 512 different CAN frames configurable
  • Supports CAN 2.0A (11 bit identifier) and CAN 2.0B (29 bit identifier)
  • Up to 1 Mbit/s CAN bit rate
  • Simple configuration via GSDML file
  • No PLC handling blocks or parameterization software necessary
  • Media redundancy (MRP client)
  • USB device interface for online diagnosis and firmware update

PROFINET/CAN-Gateway, Layer 2

General information

  • Order number700-671-PNC01
  • Article namePN/CAN gateway, CAN Layer 2
  • Scope of deliveryPN/CAN-Gateway with power plug
  • Dimensions (DxWxH)35 x 84 x 76 mm
  • WeightApprox. 160 g

PROFINET interface (X1)

  • Number1
  • Connection2x RJ45, integrated switch
  • ProtocolPROFINET IO as defined in IEC 61158-6-10
  • Transmission rate100 Mbps
  • I/O image sizemax. 1440 bytes of input / 1440 of output data
  • FeaturesMedia redundancy (MRP),
  • automatic addressing,
  • topology detection (LLDP, DCP),
  • diagnosis alarms
  • PROFINET conformance class C

 CAN interface

  • Number1
  • TypeISO/DIN 11898-2 CAN High Speed physical Layer
  • ConnectionSUB-D connector, 9 pin, male
  • Transmission rate50, 100, 125, 250, 500, 800, 1000 Kbit/s
  • ProtocolCAN Layer 2 with 11-bit or 29-bit identifier
  • FeaturesAutomatic and controlled receive and transmit objects
  • Receive channel FIFO
  • Transmit channel FIFO

USB interface

  • ProtocolFull-speed USB 2.0 device
  • ConnectionUSB-C
  • Electrical isolation500 V

Status indicator

  • Function status4 LEDs bi-color
  • Ethernet status4 LEDs

 Power supply

  • Operating supply24 V DC, 18–30 V DC
  • Current drawMax. 150 mA with 24 V DC
  • Power dissipation4 W

 Ambient conditions

  • Ambient temperature-20 °C ... +60°C
  • Transport and storage temperature-20 °C … +80 °C
  • Relative air humidity95 % r H without condensation
  • Pollution degree2
  • Protection ratingIP20
  • ApprovalsCE

PROFINET/CAN-Gateway, Layer 2

Technical Documentation
Name Version Size
EG Declaration of Confirmity 06-2019 78 KB
PN/CAN-Gateway CAN Layer 2, Quick Start Guide 5 721 KB
PN/CAN-Gateway CAN Layer 2, Manual 4 940 KB
Flyers
Name Version Size
Easy connection of fieldbus networks – with Helmholz PROFINET gateways 10-2023 1 MB
License Agreements
Name Version Size
IPSet, OpenSource license terms   25 KB
Software
Name Version Size
IPSet 1.04.016 23 MB
PN/CAN-Gateway CAN Layer 2, GSDML file 20200406 16 KB
PN/CAN Gateway CAN Layer 2, Firmware History V3.03.014 2 KB
Drivers
Name Version Size
PN/CAN-Gateway, USB driver 1.24 7 KB
Planning Tools
Name Version Size
PN/CAN-Gateway CAN Layer 2, STEP files   3 MB
PN/CAN-Gateway, STEP files   2 MB
EPLAN Data Portal, Helmholz product macros    

PROFINET/CAN-Gateway, Layer 2

The PN/CAN gateway Layer 2 allows the connection of CAN devices with proprietary CAN protocols.

On the PROFINET network, the PN/CAN gateway is a PROFINET I/O device and supports transmission rates of up to 100 Mbit full duplex; on the CAN bus, up to 1 Mbit/s is supported.

The I/O data of the CAN nodes are mapped transparently and freely configurable into the PROFINET network and can thus be processed directly in the PLC. The PN/CAN gateway is integrated into the hardware configurator with a GSDML file and can be fully configured there. Further software tools for parameterization, or handling blocks for programming, are not necessary, which makes the use of the gateway uncomplicated.

The features MRP (media redundancy) as well as extensive diagnostic functions and an interface for online diagnosis complete the performance characteristics of the PN/CAN gateway.

  • Automatic and controlled receive and transmit objects for CAN frames with configurable identifier
  • Transmission objects can also be transmitted cyclically
  • Receive channel FIFO for receiving CAN frames with flexible identifier
  • Transmission channel FIFO for transmitting any CAN frames with flexible identifier
  • Up to 512 different CAN frames configurable
  • Supports CAN 2.0A (11 bit identifier) and CAN 2.0B (29 bit identifier)
  • Up to 1 Mbit/s CAN bit rate
  • Simple configuration via GSDML file
  • No PLC handling blocks or parameterization software necessary
  • Media redundancy (MRP client)
  • USB device interface for online diagnosis and firmware update

PROFINET/CAN-Gateway, Layer 2

General information

  • Order number700-671-PNC01
  • Article namePN/CAN gateway, CAN Layer 2
  • Scope of deliveryPN/CAN-Gateway with power plug
  • Dimensions (DxWxH)35 x 84 x 76 mm
  • WeightApprox. 160 g

PROFINET interface (X1)

  • Number1
  • Connection2x RJ45, integrated switch
  • ProtocolPROFINET IO as defined in IEC 61158-6-10
  • Transmission rate100 Mbps
  • I/O image sizemax. 1440 bytes of input / 1440 of output data
  • FeaturesMedia redundancy (MRP),
  • automatic addressing,
  • topology detection (LLDP, DCP),
  • diagnosis alarms
  • PROFINET conformance class C

 CAN interface

  • Number1
  • TypeISO/DIN 11898-2 CAN High Speed physical Layer
  • ConnectionSUB-D connector, 9 pin, male
  • Transmission rate50, 100, 125, 250, 500, 800, 1000 Kbit/s
  • ProtocolCAN Layer 2 with 11-bit or 29-bit identifier
  • FeaturesAutomatic and controlled receive and transmit objects
  • Receive channel FIFO
  • Transmit channel FIFO

USB interface

  • ProtocolFull-speed USB 2.0 device
  • ConnectionUSB-C
  • Electrical isolation500 V

Status indicator

  • Function status4 LEDs bi-color
  • Ethernet status4 LEDs

 Power supply

  • Operating supply24 V DC, 18–30 V DC
  • Current drawMax. 150 mA with 24 V DC
  • Power dissipation4 W

 Ambient conditions

  • Ambient temperature-20 °C ... +60°C
  • Transport and storage temperature-20 °C … +80 °C
  • Relative air humidity95 % r H without condensation
  • Pollution degree2
  • Protection ratingIP20
  • ApprovalsCE

PROFINET/CAN-Gateway, Layer 2

Technical Documentation
Name Version Size
EG Declaration of Confirmity 06-2019 78 KB
PN/CAN-Gateway CAN Layer 2, Quick Start Guide 5 721 KB
PN/CAN-Gateway CAN Layer 2, Manual 4 940 KB
Flyers
Name Version Size
Easy connection of fieldbus networks – with Helmholz PROFINET gateways 10-2023 1 MB
License Agreements
Name Version Size
IPSet, OpenSource license terms   25 KB
Software
Name Version Size
IPSet 1.04.016 23 MB
PN/CAN-Gateway CAN Layer 2, GSDML file 20200406 16 KB
PN/CAN Gateway CAN Layer 2, Firmware History V3.03.014 2 KB
Drivers
Name Version Size
PN/CAN-Gateway, USB driver 1.24 7 KB
Planning Tools
Name Version Size
PN/CAN-Gateway CAN Layer 2, STEP files   3 MB
PN/CAN-Gateway, STEP files   2 MB
EPLAN Data Portal, Helmholz product macros