History Firmware PN/CAN Gateway CANopen (700-670-PNC01) ======================================================= V3.04.000 17.10.2024 - SDO abort bug during the CANopen device initialisizing fixed - SDO scanning for missing CANopen device(s) without the using of the device reset, now with the reset-wait-time. - cyclically sending of RPDOs now also for the TT 254 - data consistency for synchrone RPDOs improved - handling of the RTR polling timer corrected - if the function "Stop before OPERATIONAL" is use, simplified start-up prozedure with the help of the waiting of all CANopen devices with the SDO download before the generic NMT operational will be send - the function "ignore slaves" can be used in all status now V3.02.000 11.05.2023 - update of the ProfiNet stack - ProfiNet Alarme are IEC norm conform now - Alarme addeted for CAN - LED pattern for the maintenace mode implemented - Firmware is usable for the new hardware (HW4-7 and higher) - the power on booting needs more time (technical reason) - a PROFINET BF/SF LED available (HW4-7 and higher) V2.54.000 04.10.2021 - update of the ProfiNet stack - performance for the I/O data rate improved - communication freezing by worst ProfiNet settings fixed will be avoided now - faster device boot up performance now - locking bug of the CAN receiver by to many send messages fixed - status display for CAN controller offline state and their acknowledgement added - improved handling for ignored CANopen Devices - LED display bug for CAN errors corrected - PDO index administration bug if COB-IDs overflows at the range ends fixed - polling of the master status via RTR request is available now V2.06.004 28.09.2020 - now projected CANopen Devices can be ignored via PLC control - PLC parametrizing can be made done before the CANopen master send the go OPERATIONAL message - RxPDO send Bug for RxPDOs with Transmission Types 1-240 fixed - Receive bug fixed if the Tx-Puffer is full V2.06 24.01.2020 - USB stabilisized - ProfiNet handling standardisized - performance improved - longer received PDOs will be accepted - CAN disconnect detection improved - SDO 0x1018 for OEM products supported - error codes adapted and unified - 2s SDO timeout for the SDOs 0x1010 and 0x1011 - LED flashing bug fixed for the ProfiNet selection - clear emergency FIFO bug fixed - sync event monitoring for the PLC supported - SNP answers improved V1.06 24.01.2020 - only for transition update to V2.06 -- NOT OPERATIONALLY -- V1.04 27.01.2017 - LSS channel integrated - SDO receive filter is always now opened for the complete device range - COB IDs for SDO receive range is not further available for the PDO COB IDs - firmware update via service interface integreated - USB shut down bug fixed - configuration messages expanded - sporadic I&M data bug fixed - freeze of the process data fixed, with the help of steady manner communication between ProfiNet and the application (only 4 slots/msec will be processed) V1.02 05.08.2016 - LED behavior changed - RPDO shadow frames bug fixed (if only transmission typs 1 - 240 is used) - PNO certification - overflow of PDO number in association with the node id will be create a error message - some little bug fixed - process data up to 1440 bytes are now usable - empty I&M0 data bug fixed V1.00 10.11.2015 - 1. Release