Skip to main content Skip to search Skip to main navigation

PROFINET Coupler, EtherNet/IP

With the PN/EtherNetIP Coupler, a simple and uncomplicated connection of a PROFINET machine to an EtherNet/IP machine is possible. The PN/EtherNetIP Coupler allows data transmission between a PROFINET controller and an EtherNet/IP PLC.

Received input data on one side of the network are made available as output data on the other side of the network to the PLC. The I/O data exchange takes place live and as fast as possible without further handling blocks.

The maximum size of the transferable I/O data is 1024 bytes. Up to 3 input and 3 output assemblies can be configured on the EtherNet/IP network side. Up to 300 slots are available for I/O modules.

The integration into the PLC engineering tool is made possible by a GSDML file, an extra configuration software is not necessary. The configuration of the I/O data to be exchanged is performed in the Siemens engineering tool. An EDS file matching the configuration can then be downloaded from the website by the PN/EtherNetIP Coupler and used to configure the EtherNet/IP PLC.

  • Very compact design for DIN rail mounting
  • Redundant power supply
  • Galvanic isolation of the networks
  • Up to 1024 Byte input/output data
  • 300 configurable slots for PROFINET IO data
  • 3 input and 3 output assemblies
  • Configuration just with GSDML file, no further software necessary
  • EDS file downloadable
  • Diagnostics website
  • MQTT Publisher on both network sides (PROFINET & Ethernet/IP)

PROFINET Coupler, EtherNet/IP

General information

  • Order number700-160-3EN02
  • Article namePN/EtherNetIP Coupler
  • Scope of deliveryPN/EtherNetIP Coupler with power supply plug
  • Dimensions (DxWxH)32.5 x 58.5 x 76 mm mm
  • WeightApprox. 135 g

PROFINET interface (X1)

  • Number1
  • Connection2 x RJ45, integrated switch
  • ProtocolPROFINET IO Device as defined in IEC 61158-6-10
  • Transmission rate100 Mbps full duplex
  • I/O image sizemax. 1024 bytes of input and output data
  • Featuresmedia redundancy(MRP-Client),
  • automatic addressing,
  • Topologieerkennung (LLDP, DCP),
  • diagnosis alarms
  • PROFINET conformance class B

EtherNet/IP interface (X2)

  • Number1
  • Connection2x RJ45, integrated switch
  • ProtocolEtherNet/IP
  • implicit messaging (Transport Class 1)
  • explicit messaging (Transport Class 3)
  • Transmission rate10/100 Mbit/s, full-/half duplex
  • I/O image size3x input assemblies + 3x output assemblies
  • together maximum 1024 bytes data
  • Number of the assemblies adjustable

Status indicator

  • Function indicator9 LEDs
  • Ethernet status8 LEDs

Power supply

  • Operating voltage24 V DC (18 - 28 V DC)
  • Current drawmax. 140 mA
  • Power dissipationmax. 3.4 W

Ambient conditions

  • Ambient temperature0 °C to 60 °C
  • Transport and storage temperature-20 °C to 80 °C
  • Relative air humidity95% non-condensing
  • Protection ratingIP 20
  • Mounting positionas desired
  • ApprovalsCE, UL

UL

  • ULUL 61010-1 / UL 61010-2-201
  • Surrounding Air TemperatureDC 24 V (18 ... 28 VDC, SELV and limited energy circuit)
  • Pollution degree2
  • AltitudeUp to 2000m
  • Temperature cable rating87 °C

 

PROFINET Coupler, EtherNet/IP

Technical Documentation
Name Version Size
PN/EthernetIP Coupler, Quick Start Guide 4 788 KB
PN/EthernetIP Coupler, PROFINET-Certificate   82 KB
EU Declaration of Confirmity 04-2020 53 KB
Flyers
Name Version Size
Easy connection of fieldbus networks – with Helmholz PROFINET gateways 10-2023 1 MB
Software
Name Version Size
PN/EtherNetIP Coupler, GSDML file 20220518 11 KB
PN/EtherNetIP Coupler, Firmware V1.04.006 12 MB
Planning Tools
Name Version Size
PN/EtherNetIP Coupler, STEP files   13 MB
EPLAN Data Portal, Helmholz product macros    

PROFINET Coupler, EtherNet/IP

With the PN/EtherNetIP Coupler, a simple and uncomplicated connection of a PROFINET machine to an EtherNet/IP machine is possible. The PN/EtherNetIP Coupler allows data transmission between a PROFINET controller and an EtherNet/IP PLC.

Received input data on one side of the network are made available as output data on the other side of the network to the PLC. The I/O data exchange takes place live and as fast as possible without further handling blocks.

The maximum size of the transferable I/O data is 1024 bytes. Up to 3 input and 3 output assemblies can be configured on the EtherNet/IP network side. Up to 300 slots are available for I/O modules.

The integration into the PLC engineering tool is made possible by a GSDML file, an extra configuration software is not necessary. The configuration of the I/O data to be exchanged is performed in the Siemens engineering tool. An EDS file matching the configuration can then be downloaded from the website by the PN/EtherNetIP Coupler and used to configure the EtherNet/IP PLC.

  • Very compact design for DIN rail mounting
  • Redundant power supply
  • Galvanic isolation of the networks
  • Up to 1024 Byte input/output data
  • 300 configurable slots for PROFINET IO data
  • 3 input and 3 output assemblies
  • Configuration just with GSDML file, no further software necessary
  • EDS file downloadable
  • Diagnostics website
  • MQTT Publisher on both network sides (PROFINET & Ethernet/IP)

PROFINET Coupler, EtherNet/IP

General information

  • Order number700-160-3EN02
  • Article namePN/EtherNetIP Coupler
  • Scope of deliveryPN/EtherNetIP Coupler with power supply plug
  • Dimensions (DxWxH)32.5 x 58.5 x 76 mm mm
  • WeightApprox. 135 g

PROFINET interface (X1)

  • Number1
  • Connection2 x RJ45, integrated switch
  • ProtocolPROFINET IO Device as defined in IEC 61158-6-10
  • Transmission rate100 Mbps full duplex
  • I/O image sizemax. 1024 bytes of input and output data
  • Featuresmedia redundancy(MRP-Client),
  • automatic addressing,
  • Topologieerkennung (LLDP, DCP),
  • diagnosis alarms
  • PROFINET conformance class B

EtherNet/IP interface (X2)

  • Number1
  • Connection2x RJ45, integrated switch
  • ProtocolEtherNet/IP
  • implicit messaging (Transport Class 1)
  • explicit messaging (Transport Class 3)
  • Transmission rate10/100 Mbit/s, full-/half duplex
  • I/O image size3x input assemblies + 3x output assemblies
  • together maximum 1024 bytes data
  • Number of the assemblies adjustable

Status indicator

  • Function indicator9 LEDs
  • Ethernet status8 LEDs

Power supply

  • Operating voltage24 V DC (18 - 28 V DC)
  • Current drawmax. 140 mA
  • Power dissipationmax. 3.4 W

Ambient conditions

  • Ambient temperature0 °C to 60 °C
  • Transport and storage temperature-20 °C to 80 °C
  • Relative air humidity95% non-condensing
  • Protection ratingIP 20
  • Mounting positionas desired
  • ApprovalsCE, UL

UL

  • ULUL 61010-1 / UL 61010-2-201
  • Surrounding Air TemperatureDC 24 V (18 ... 28 VDC, SELV and limited energy circuit)
  • Pollution degree2
  • AltitudeUp to 2000m
  • Temperature cable rating87 °C

 

PROFINET Coupler, EtherNet/IP

Technical Documentation
Name Version Size
PN/EthernetIP Coupler, Quick Start Guide 4 788 KB
PN/EthernetIP Coupler, PROFINET-Certificate   82 KB
EU Declaration of Confirmity 04-2020 53 KB
Flyers
Name Version Size
Easy connection of fieldbus networks – with Helmholz PROFINET gateways 10-2023 1 MB
Software
Name Version Size
PN/EtherNetIP Coupler, GSDML file 20220518 11 KB
PN/EtherNetIP Coupler, Firmware V1.04.006 12 MB
Planning Tools
Name Version Size
PN/EtherNetIP Coupler, STEP files   13 MB
EPLAN Data Portal, Helmholz product macros