Analog-input-module, TC, Iso., 16 Bit

The scope of delivery already includes the appropriate front connector for the cabling and a base module. The module has 4 analog inputs for connecting thermocouples.

Parameters for the module

Diagnostic alarm: On | Off
Overflow/underflow diagnosis: On | Off
Representation values: SIMATIC* S7 | SIMATIC* S5 (for ±80 mV only)
Temperature unit: Celsius x 10 | Fahrenheit x 10 | Kelvin x 10

Parameters for each channel

Wire break detection: On | Off
Interference frequency suppression: None | 10 Hz | 50 Hz | 60 Hz | 400 Hz
Measuring ranges: ±80 mV
Thermocouples: E | J | K | N | R | S | T | B | C | L
Temperature compensation: Internal | External | Process data-based
Limit value alarms enabled: On | Off
Upper/lower limit: 16 bit analog value (±27648)

* SIMATIC is a registered trademark of Siemens AG.

  • Measuring range ±80 mV
  • Supported thermocouples: E, J, K, N, R, S, T, B, C, L
  • Measurement resolution: 15 bits + sign
  • External or internal temperature compensation
  • Wire break detection
  • Diagnostic messages
  • Limit value alarms for each channel
  • A bi-color LED (blue/red) indicates the module operating status and any malfunctions
  • Red/green bi-color LEDs (one for each channel) indicate the channel status
  • 4 inputs, electrically isolated from the backplane bus
  • 4 process input words
  • 4 process output words (for temperature compensation)

Analog-input-module, TC, Iso., 16 Bit

General information

  • Order number600-254-4AD02
  • Article nameAI 4x TC, Iso., 16 bit
  • Scope of deliveryAI 4x TC, Iso., 16 bit
  • Dimensions (DxWxH)110 x 14 x 73 mm
  • WeightApprox. 70 g
  • Number of inputs4
  • InternalMax. 95 mA
  • Power dissipationMax. 0.7 W
  • Parameter configuration length26 bytes
  • General error indicatorRed LED
  • Hot-swap capableYes
  • Hot-swap capableYes

Electrical isolation

  • from the backplane busYes
  • Between the channelsYes

Measuring

  • Measuring ranges± 80 mV
  • ThermocouplesE (-270 °C … 990 °C)
  • J (-210 °C ... 1200 °C)
  • K (-270 °C … 1380 °C)
  • N (-270 °C … 1320 °C)
  • R (-50 °C … 1775 °C)
  • S (-50 °C … 1775 °C)
  • T (-270 °C … 405 °C)
  • B (0 °C … 1800 °C)
  • C (0 °C … 2320 °C)
  • L (0 °C … 900 °C)
  • Measuring methodIntegration
  • Measurement resolution15 bits + sign
  • Interference frequency suppressionNone | 10 Hz | 50 Hz | 60 Hz | 400 Hz
  • Refresh rate / conversion rateDepends on the interference frequency suppression setting being used:
  • None: 2.5 ms
  • 400 Hz: 8 ms
  • 60 Hz: 51 ms
  • 50 Hz: 60 ms
  • 10 Hz: 160 ms
  • DiagnosesUpper measuring range limit exceeded (overflow), lower measuring range limit fallen below (underflow), parameter assignment error
  • Process alarmsUpper and lower limit per channel

Error limits

  • Operational error limit in the entire temperature range±0.5 % relative to the nominal range
  • Basic error limit at 25 °C±0.3 % relative to the nominal range
  • Temperature error±0.005 %/K relative to the nominal range
  • Linearity error±0.05 %/K relative to the nominal range
  • Repeating accuracy in steady state at 25 °C±0.05 %/K relative to the nominal range

Ambient conditions

  • Ambient temperature0 °C … +60 °C
  • Transport and storage temperature-20 °C … +80 °C
  • Relative air humidity95 % r H without condensation
  • Protection ratingIP 20
  • CertificationsCE, UL

UL

  • Surrounding Air Temperature0 °C … +60°C
  • Pollution degree2

CE

  • Noise immunityDIN EN 61000-6-2 “EMC Immunity”
  • Interference emissionDIN EN 61000-6-4 “EMC Emission”
  • Vibration and shock resistanceDIN EN 60068-2-6:2008 „Vibration“, DIN EN 60068-2-27:2010 „Shock"

Analog-input-module, TC, Iso., 16 Bit

Technical Documentation
Name Version Size
TB20, Manual Modules 15 8 MB
Flyers
Name Version Size
Flyer, TB20 IO-system for numerous applications 08-2022 6 MB
Planning Tools
Name Version Size
AI 4x TC, Iso., 16 Bit, STEP Files   3 MB

Analog-input-module, TC, Iso., 16 Bit

The scope of delivery already includes the appropriate front connector for the cabling and a base module. The module has 4 analog inputs for connecting thermocouples.

Parameters for the module

Diagnostic alarm: On | Off
Overflow/underflow diagnosis: On | Off
Representation values: SIMATIC* S7 | SIMATIC* S5 (for ±80 mV only)
Temperature unit: Celsius x 10 | Fahrenheit x 10 | Kelvin x 10

Parameters for each channel

Wire break detection: On | Off
Interference frequency suppression: None | 10 Hz | 50 Hz | 60 Hz | 400 Hz
Measuring ranges: ±80 mV
Thermocouples: E | J | K | N | R | S | T | B | C | L
Temperature compensation: Internal | External | Process data-based
Limit value alarms enabled: On | Off
Upper/lower limit: 16 bit analog value (±27648)

* SIMATIC is a registered trademark of Siemens AG.

  • Measuring range ±80 mV
  • Supported thermocouples: E, J, K, N, R, S, T, B, C, L
  • Measurement resolution: 15 bits + sign
  • External or internal temperature compensation
  • Wire break detection
  • Diagnostic messages
  • Limit value alarms for each channel
  • A bi-color LED (blue/red) indicates the module operating status and any malfunctions
  • Red/green bi-color LEDs (one for each channel) indicate the channel status
  • 4 inputs, electrically isolated from the backplane bus
  • 4 process input words
  • 4 process output words (for temperature compensation)

Analog-input-module, TC, Iso., 16 Bit

General information

  • Order number600-254-4AD02
  • Article nameAI 4x TC, Iso., 16 bit
  • Scope of deliveryAI 4x TC, Iso., 16 bit
  • Dimensions (DxWxH)110 x 14 x 73 mm
  • WeightApprox. 70 g
  • Number of inputs4
  • InternalMax. 95 mA
  • Power dissipationMax. 0.7 W
  • Parameter configuration length26 bytes
  • General error indicatorRed LED
  • Hot-swap capableYes
  • Hot-swap capableYes

Electrical isolation

  • from the backplane busYes
  • Between the channelsYes

Measuring

  • Measuring ranges± 80 mV
  • ThermocouplesE (-270 °C … 990 °C)
  • J (-210 °C ... 1200 °C)
  • K (-270 °C … 1380 °C)
  • N (-270 °C … 1320 °C)
  • R (-50 °C … 1775 °C)
  • S (-50 °C … 1775 °C)
  • T (-270 °C … 405 °C)
  • B (0 °C … 1800 °C)
  • C (0 °C … 2320 °C)
  • L (0 °C … 900 °C)
  • Measuring methodIntegration
  • Measurement resolution15 bits + sign
  • Interference frequency suppressionNone | 10 Hz | 50 Hz | 60 Hz | 400 Hz
  • Refresh rate / conversion rateDepends on the interference frequency suppression setting being used:
  • None: 2.5 ms
  • 400 Hz: 8 ms
  • 60 Hz: 51 ms
  • 50 Hz: 60 ms
  • 10 Hz: 160 ms
  • DiagnosesUpper measuring range limit exceeded (overflow), lower measuring range limit fallen below (underflow), parameter assignment error
  • Process alarmsUpper and lower limit per channel

Error limits

  • Operational error limit in the entire temperature range±0.5 % relative to the nominal range
  • Basic error limit at 25 °C±0.3 % relative to the nominal range
  • Temperature error±0.005 %/K relative to the nominal range
  • Linearity error±0.05 %/K relative to the nominal range
  • Repeating accuracy in steady state at 25 °C±0.05 %/K relative to the nominal range

Ambient conditions

  • Ambient temperature0 °C … +60 °C
  • Transport and storage temperature-20 °C … +80 °C
  • Relative air humidity95 % r H without condensation
  • Protection ratingIP 20
  • CertificationsCE, UL

UL

  • Surrounding Air Temperature0 °C … +60°C
  • Pollution degree2

CE

  • Noise immunityDIN EN 61000-6-2 “EMC Immunity”
  • Interference emissionDIN EN 61000-6-4 “EMC Emission”
  • Vibration and shock resistanceDIN EN 60068-2-6:2008 „Vibration“, DIN EN 60068-2-27:2010 „Shock"

Analog-input-module, TC, Iso., 16 Bit

Technical Documentation
Name Version Size
TB20, Manual Modules 15 8 MB
Flyers
Name Version Size
Flyer, TB20 IO-system for numerous applications 08-2022 6 MB
Planning Tools
Name Version Size
AI 4x TC, Iso., 16 Bit, STEP Files   3 MB