Skip to main content Skip to search Skip to main navigation

Analoge-output-module, I, 12 Bit 4x

The scope of delivery already includes the appropriate front connector for the cabling and a base module. The module has 4 analogue outputs.

  • Output range 0 ... 20 mA, 4 ... 20 mA
  • Resolution 12 bit
  • Substitute value functionality
  • Diagnostic messages
  • A bi-color LED (blue/red) indicates the module operating status and any malfunctions
  • 4 analog outputs, electrically isolated from the backplane bus
  • 4 process output words (4 bytes)

Analoge-output-module, I, 12 Bit 4x

General information

  • Order number600-260-4AD01
  • Article nameAO 4x I, 0/4 ... 20 mA, 12 bit
  • Scope of deliveryAO 4x I, 0/4 ... 20 mA, 12 bit
  • Dimensions (DxWxH)110 x 14 x 73 mm
  • WeightApprox. 70 g
  • Number of outputs4
  • Parameter configuration length13 bytes
  • General error indicatorRed LED
  • Hot-swap capableYes
  • Power dissipationMax. 3 W

Output

  • Output ranges0 … 20 mA,
  • 4 … 20 mA
  • Connection for actuators2-wire connection
  • Load resistanceMax. 600 ohms
  • Inductive loadMax. 100 mH
  • No-load voltagemax. 18 V
  • Measurement resolution12 bit
  • Refresh time0.2 ms
  • Settling time0.2 ms for resistive loads,
  • 2.2 ms for capacitive loads,
  • 0.5 ms for inductive loads (<=1 mH),
  • 3.3 ms for inductive loads (<=3.3 mH)
  • DiagnosesExternal reference voltage missing (L+), wire break, parameter assignment error
  • Process alarmsUpper and lower limit per channel
  • Process alarmsUpper and lower limit per channel

Electrical isolation

  • from the backplane busYes
  • Between the channelsNo

Current draw

  • ExternalMax. 100 mA
  • InternalMax. 26 mA

Error limits

  • Operational error limit in the entire temperature range±0.5 % relative to the nominal range
  • Basic error limit at 25 °C±0.3 % relative to the nominal range
  • Temperature error±0.005 %/K relative to the nominal range
  • Linearity error±0.05 %/K relative to the nominal range
  • Repeating accuracy in steady state at 25 °C±0.05 %/K relative to the nominal range
  • Repeating accuracy in steady state at 25 °C±0.05 %/K relative to the nominal range

Ambient conditions

  • Ambient temperature0 °C … +60 °C
  • Transport and storage temperature-20 °C … +80 °C
  • Relative air humidity95 % r H without condensation
  • Protection ratingIP 20
  • CertificationsCE, UL

UL

  • Surrounding Air Temperature0 °C … +60°C
  • Pollution degree2

CE

  • Noise immunityDIN EN 61000-6-2 “EMC Immunity”
  • Interference emissionDIN EN 61000-6-4 “EMC Emission”
  • Vibration and shock resistanceDIN EN 60068-2-6:2008 „Vibration“, DIN EN 60068-2-27:2010 „Shock"

Analoge-output-module, I, 12 Bit 4x

Technical Documentation
Name Version Size
TB20, Manual Modules 15 8 MB
Flyers
Name Version Size
Flyer, TB20 IO-system for numerous applications 08-2022 6 MB
Planning Tools
Name Version Size
AO 4 x I, 0/4...20 mA, 12 Bit, STEP Files   3 MB

Analoge-output-module, I, 12 Bit 4x

The scope of delivery already includes the appropriate front connector for the cabling and a base module. The module has 4 analogue outputs.

  • Output range 0 ... 20 mA, 4 ... 20 mA
  • Resolution 12 bit
  • Substitute value functionality
  • Diagnostic messages
  • A bi-color LED (blue/red) indicates the module operating status and any malfunctions
  • 4 analog outputs, electrically isolated from the backplane bus
  • 4 process output words (4 bytes)

Analoge-output-module, I, 12 Bit 4x

General information

  • Order number600-260-4AD01
  • Article nameAO 4x I, 0/4 ... 20 mA, 12 bit
  • Scope of deliveryAO 4x I, 0/4 ... 20 mA, 12 bit
  • Dimensions (DxWxH)110 x 14 x 73 mm
  • WeightApprox. 70 g
  • Number of outputs4
  • Parameter configuration length13 bytes
  • General error indicatorRed LED
  • Hot-swap capableYes
  • Power dissipationMax. 3 W

Output

  • Output ranges0 … 20 mA,
  • 4 … 20 mA
  • Connection for actuators2-wire connection
  • Load resistanceMax. 600 ohms
  • Inductive loadMax. 100 mH
  • No-load voltagemax. 18 V
  • Measurement resolution12 bit
  • Refresh time0.2 ms
  • Settling time0.2 ms for resistive loads,
  • 2.2 ms for capacitive loads,
  • 0.5 ms for inductive loads (<=1 mH),
  • 3.3 ms for inductive loads (<=3.3 mH)
  • DiagnosesExternal reference voltage missing (L+), wire break, parameter assignment error
  • Process alarmsUpper and lower limit per channel
  • Process alarmsUpper and lower limit per channel

Electrical isolation

  • from the backplane busYes
  • Between the channelsNo

Current draw

  • ExternalMax. 100 mA
  • InternalMax. 26 mA

Error limits

  • Operational error limit in the entire temperature range±0.5 % relative to the nominal range
  • Basic error limit at 25 °C±0.3 % relative to the nominal range
  • Temperature error±0.005 %/K relative to the nominal range
  • Linearity error±0.05 %/K relative to the nominal range
  • Repeating accuracy in steady state at 25 °C±0.05 %/K relative to the nominal range
  • Repeating accuracy in steady state at 25 °C±0.05 %/K relative to the nominal range

Ambient conditions

  • Ambient temperature0 °C … +60 °C
  • Transport and storage temperature-20 °C … +80 °C
  • Relative air humidity95 % r H without condensation
  • Protection ratingIP 20
  • CertificationsCE, UL

UL

  • Surrounding Air Temperature0 °C … +60°C
  • Pollution degree2

CE

  • Noise immunityDIN EN 61000-6-2 “EMC Immunity”
  • Interference emissionDIN EN 61000-6-4 “EMC Emission”
  • Vibration and shock resistanceDIN EN 60068-2-6:2008 „Vibration“, DIN EN 60068-2-27:2010 „Shock"

Analoge-output-module, I, 12 Bit 4x

Technical Documentation
Name Version Size
TB20, Manual Modules 15 8 MB
Flyers
Name Version Size
Flyer, TB20 IO-system for numerous applications 08-2022 6 MB
Planning Tools
Name Version Size
AO 4 x I, 0/4...20 mA, 12 Bit, STEP Files   3 MB