PROFINET/CAN-Gateway SLIM, CANopen Slave
The PN/CAN gateway SLIM enables simple and straightforward connection of CAN devices to a PROFINET network. On the CAN side, various CAN protocol variants are supported.€581.00
PROFINET/CAN-Gateway SLIM, CANopen Slave
The PN/CAN gateway "CANopen Slave" enables the coupling of machines with CANopen bus to machines with PROFINET network and represents a freely configurable full CANopen Slave Device at the CAN bus.
On the PROFINET network the PN/CAN gateway "CANopen Slave" is a PROFINET I/O device and supports transfer rates up to 100 Mbit full duplex. The data of the CANopen SDOs are transparently and freely configurably inserted into the PROFINET network and can thus be read or written directly in the PLC.
The PN/CAN gateway is integrated into the hardware configurator of the PROFINET controller with a GSDML file, and all values of the CANopen slave are available as IO information. Special handling blocks are not necessary. An EDS or DCF file is used to permanently load a plant-specific CANopen device configuration into the device.
The gateway supports CANopen network management, nodeguarding/heartbeat, emergencies and SDO accesses on the CAN bus. Up to 16 RX- and Tx-PDOs can be parameterized. It is also possible to parameterize the CANopen device including PDO mapping via the CAN bus and to send customer specific emergency messages. The features PROFINET MRP (media redundancy) as well as extensive diagnostic functions and an interface for online diagnostics complete the performance features of the PN/CAN gateway.
- CANopen Slave Device according to CANopen protocol DSP 301
- Up to 16 TPDOs / 16 RPDOs
- Up to 1420 bytes input and 1420 bytes output data on PROFINET
- Up to 1 Mbit/s CAN bit rate
- CANopen NMT, Heartbeat, Nodeguarding, Emergency
- PROFINET Conformance Class C
- PROFINET media redundancy (MRP client)
- Configuration via EDS/DCF file and GSDML file
- No handling blocks necessary
- USB device interface for loading the configuration, online diagnosis and firmware update
PROFINET/CAN-Gateway SLIM, CANopen Slave
General Information
- Order-no.700-672-PNC51
- NamePROFINET/CAN-Gateway SLIM, CANopen Slave
- Scope of deliveryPROFINET/CAN-Gateway SLIM with power plug
- Diemnsions (D x W xH)65 x 25 x 109 mm
- WeightApprox. 160g
PROFINET-interface
- Number1
- Connection2x RJ45, integrated Switch
- Transmission rate100 MBpbs, full dupley
- ProtocolPROFINET IO Device as defined in IEC 61158-6-10
- I/O image sizemax. 1440 bytes inputdata / 1440 bytes outputdata
- FeaturesPROFINET Conformance Class C, Media redundancy (MRP client), Automatic addressing, Topology detection (LLDP, DCP), Diagnosis alarms
CAN-interface
- Number1
- TypeISO/DIN 11898-2 CAN High Speed physical Layer
- Connection9-pin D-sub male connector
- Baud rate10, 50, 100, 125, 250, 500, 800, 1000 kbps
- ProtocolCANopen according in DSP301 V4.2
- TPDOs16
- RPDOs16
- FeaturesNMT, Heartbeat, Nodeguarding, Sync
USB interface
- ProtocolUSB 2.0 Device, Full Speed
- ConnectionUSB-C
- Electrically isolation500 V
Status indicator
- Function status4 LEDs, bi-color
- Ethernet status4 LEDs
Power supply
- Operating voltage24 V DC, 18 - 30 V DC
- Current drawmax. 105mA at 24 V DC
- Power dissipationmax. 2,6 W
Ambient conditions
- Ambient temperature-40°C bis +75°C
- Transport and storage temperature-40°C bis +80°C
- Relative humidity95% without condensation
- Pollution degree2
- Protection ratingIP 20
- Mounting positionas desired
- ApprovalsCE
PROFINET/CAN-Gateway SLIM, CANopen Slave
PROFINET/CAN-Gateway SLIM, CANopen Slave
The PN/CAN gateway "CANopen Slave" enables the coupling of machines with CANopen bus to machines with PROFINET network and represents a freely configurable full CANopen Slave Device at the CAN bus.
On the PROFINET network the PN/CAN gateway "CANopen Slave" is a PROFINET I/O device and supports transfer rates up to 100 Mbit full duplex. The data of the CANopen SDOs are transparently and freely configurably inserted into the PROFINET network and can thus be read or written directly in the PLC.
The PN/CAN gateway is integrated into the hardware configurator of the PROFINET controller with a GSDML file, and all values of the CANopen slave are available as IO information. Special handling blocks are not necessary. An EDS or DCF file is used to permanently load a plant-specific CANopen device configuration into the device.
The gateway supports CANopen network management, nodeguarding/heartbeat, emergencies and SDO accesses on the CAN bus. Up to 16 RX- and Tx-PDOs can be parameterized. It is also possible to parameterize the CANopen device including PDO mapping via the CAN bus and to send customer specific emergency messages. The features PROFINET MRP (media redundancy) as well as extensive diagnostic functions and an interface for online diagnostics complete the performance features of the PN/CAN gateway.
- CANopen Slave Device according to CANopen protocol DSP 301
- Up to 16 TPDOs / 16 RPDOs
- Up to 1420 bytes input and 1420 bytes output data on PROFINET
- Up to 1 Mbit/s CAN bit rate
- CANopen NMT, Heartbeat, Nodeguarding, Emergency
- PROFINET Conformance Class C
- PROFINET media redundancy (MRP client)
- Configuration via EDS/DCF file and GSDML file
- No handling blocks necessary
- USB device interface for loading the configuration, online diagnosis and firmware update
PROFINET/CAN-Gateway SLIM, CANopen Slave
General Information
- Order-no.700-672-PNC51
- NamePROFINET/CAN-Gateway SLIM, CANopen Slave
- Scope of deliveryPROFINET/CAN-Gateway SLIM with power plug
- Diemnsions (D x W xH)65 x 25 x 109 mm
- WeightApprox. 160g
PROFINET-interface
- Number1
- Connection2x RJ45, integrated Switch
- Transmission rate100 MBpbs, full dupley
- ProtocolPROFINET IO Device as defined in IEC 61158-6-10
- I/O image sizemax. 1440 bytes inputdata / 1440 bytes outputdata
- FeaturesPROFINET Conformance Class C, Media redundancy (MRP client), Automatic addressing, Topology detection (LLDP, DCP), Diagnosis alarms
CAN-interface
- Number1
- TypeISO/DIN 11898-2 CAN High Speed physical Layer
- Connection9-pin D-sub male connector
- Baud rate10, 50, 100, 125, 250, 500, 800, 1000 kbps
- ProtocolCANopen according in DSP301 V4.2
- TPDOs16
- RPDOs16
- FeaturesNMT, Heartbeat, Nodeguarding, Sync
USB interface
- ProtocolUSB 2.0 Device, Full Speed
- ConnectionUSB-C
- Electrically isolation500 V
Status indicator
- Function status4 LEDs, bi-color
- Ethernet status4 LEDs
Power supply
- Operating voltage24 V DC, 18 - 30 V DC
- Current drawmax. 105mA at 24 V DC
- Power dissipationmax. 2,6 W
Ambient conditions
- Ambient temperature-40°C bis +75°C
- Transport and storage temperature-40°C bis +80°C
- Relative humidity95% without condensation
- Pollution degree2
- Protection ratingIP 20
- Mounting positionas desired
- ApprovalsCE